This bioanalytical method is the most common and is used for automation and unattended analysis. It is a very robust, versatile, and sensitive methodology that is used by small molecules. Many features and functions of the method are similar to HPLC/UV. It is used before MS detection and UV Detection. As we have read about the detection method, MS- Mass Spectrometry relies on the mass-to-charge ratio of a compound. In the chromatographic separation and the energy source, the molecules are ionized.
LG MS MS test widely used for biological samples, such as analysis of compounds that lack chromophores, updating existing methodology, and structure confirmation analyses. The other trace analysis features are used in environmental samples and pharmaceutical analyses.
The major problem that is associated with the detection method is controlling the ionization process. The loopholes that are linked with incomplete ionization and interference can give rise to different problems. The major being- accuracy and poor precision. For that, a huge number of technologies and solvents, ionization techniques, even chromatographic separations.
Failure mode effects Investigation
Download
Risk and Failure analysis, Mitigation and Corrective services.
Detector’s high specificity makes it possible to continue without any confirmatory detection method. It is one of the biggest advantages. The property of high sensitivity helps to detect some compounds that are below 1 part per trillion. In addition to that, excellent reproducibility is another strength of the detection method.
The strength of this detection method lies in the power of LC. It depends on a wide range of combined compounds with the capability of Mass Spectrometry. The main motive is to quantify compounds with a high level of selectivity and sensitivity based on unique mass/charge (m/z) transitions.
The process of detecting the compounds is carried out in charged particles that strike a detector and create a current.
The additional features and steps needed are ion capture MS, time of flight MS and others. To successfully carry out the improvement process, we need unique methods and use different MS detector setups. Accuracy, better sensitivity, and precision would be the result. And all these can be achieved here with our experts.
LC-MS/MS With Nishka Research
Nishka Research Centre comprises a team of data scientists and other scholarly geniuses who work with perfection. The team of well-qualified and highly versed understand the usage of bioanalysis and fundamental tenets of the technology. Our sophisticated technology platform is growing at a very fast rate. The virtualization of clinical research, as well as development, makes us deliver as per the expectations.
We work to minimize the limitations of the technology and provide the best results. We combine the separating power of both mass spectrometry and liquid chromatography. We work on a large variety of mobile phase combinations and stationary phases, allowing us to come up with customizing. This makes us powerful to deliver the best possible solutions even to the most complex problems.
Please fill the required information for Downloading White Paper.
Need help or Have a question?
Nishka Research Pvt. Ltd.
Regus Business Center,
4th floor, Gumidelli Commercial Complex,
1-10-39 to 44, Old Airport Road, Begumpet,
Hyderabad-500016
India
Phone : +91 40 29303155
Mobile : +91 7842798518
Left us a
star review